PYRANOMETER MS-802 – ISO9060 SECONDARY STANDARD
- ISO 9060 Secondary Standard”
- Max irradiance: 2000 W/m²
- Sensitivity: ~7 µV/W/m²
- Spectral range: 285 … 2800 nm
- Non-linearity: < 0.2%
- Response time (95%): < 5s
- Operating temperature: -40 … +80°C
- Delivery includes calibration certificate.
PYRANOMETER CMP 10 – ISO 9060 SECONDARY STANDARD
- Secondary Standard”, WMO + ISO 9060
- Applicable as refence instrument due to its measurement precision
- Easy to adjust horizontally due to adjustable feet and a level
- Max. irradiance: 4000 W/m²
- Sensitivity: 7 … 14 µV/W/m²
- Spectral range: 285 … 2800 nm
- Linearity: < 0.2% (0 … 1000 W/m²)
- Operating temperature: – 40 … +80°C
- Delivery includes calibration certificate
PYRANOMETER CMP 11 – ISO 9060 SECONDARY STANDARD
- Secondary Standard”, WMO + ISO 9060
- Applicable as refence instrument due to its measurement precision
- Easy to adjust horizontally due to adjustable feet and a level
- Max. irradiance: 4000 W/m²
- Sensitivity: 7 … 14 µV/W/m²
- Spectral range: 285 … 2800 nm
- Linearity: < 0.2% (0 … 1000 W/m²)
- Operating temperature: – 40 … +80°C
- Delivery includes calibration certificate
PYRANOMETER MS-410 – ISO9060 FIRST CLASS
- ISO 9060 First Class”
- Max. irradiance: 2000 W/m²
- Sensitivity: ~7 µV/W/m²
- Spectral range: 285 … 2800 nm
- Non-linearity: < 1%
- Response time (95%): < 18s
- Operating temperature: -40 … +80°C
- Delivery includes calibration certificate
PYRANOMETER CMP 6 – ISO 9060 FIRST CLASS
- First Class”, WMO + ISO 9060
- Easy to adjust horizontally due to adjustable feet and a level
- Max. irradiance: 2000 W/m²
- Sensitivity: 5 … 20 µV/W/m²
- Spectral range: 285 … 2800 nm
- Non-Linearity: < 1% (0 … 1000 W/m²)
- Operating termperature: -40 … +80°C
- Delivery includes calibration certificate
PYRANOMETER MS-602 – ISO 9060 SECOND CLASS
- ISO 9060 Second Class”
- Max. irradiance: 2000 W/m²
- Sensitivity: ~7 µV/W/m²
- Spectral range: 285 … 2800 nm
- Non-linearity: < 1.5%
- Response time (95%): < 17s
- Operating temperature: -40 … +80°C
- Delivery includes calibration certificate
PYRANOMETER CMP 3 – ISO 9060 SECOND CLASS
- Second Class”, WMO + ISO 9060
- Max. irradiance: 2000 W/m²
- Sensitivity: 5 … 20 µV/W/m²
- Spectral range: 300 … 2800 nm
- Non-Linearity: < 1% (0 .. 1000 W/m²)
- Response time (95%): 18s
- Operating temperature: -40 … +80° C
- Delivery includes calibration certificate
DELTA-T SUNSHINE PYRANOMETER SPN 1
- WMO sun threshold: 120 W/m² direct beam
- Unique glass dome
- Wideband thermopile sensors
- Near ideal spectral and cosinus response
- Accuracy (cosine corr.) ± 2% of incoming radiation over0-90° Zenith angle
- Diffuse Radiation: ± 8% ± 10 W/m² individual
- Global (Total): ± 5% ± 10 W/m² hourly average
- Accuracy: ± 5% daily intervals
- Non-Linearity: < 1%
- Measurement range: 0 … >2000 W/m²
- Spectral range: 400 … 2700 nm
- Temperature range: – 40 … +70
SUNSHINE DURATION SENSOR CSD3
- Spectral range: 400 … 1100 nm
- Resonse time: < 1 ms
- Accuracy of sunshine hours: > 90% (monthly sunshine hours)
- Accuracy of direct signal: > 90% @ W/m²
- Stability: < 2% change per year
- Temperature dependence: < 0.1%/K
- Operating temperature: -40 … 70°C
- Impedance: 1 kO
PYRHELIOMETER MS-56 – ISO 9060 FIRST CLASS
- ISO 9060 “First Class”
- Sensitivity: 6 … 10 µV/W/m²
- Spectral range: 200 … 4000 nm
- Max. irradiance: 2000 W/m²
- Signal output: 0 … 10mV
- Non-linearity (100 … 1000 W/m²): < ±0,5%
- Temperature dependence: < ±0,5% (-20 ... 50°C @ 20°C)
- Operating temperature: -40 … +80°C
PYRHELIOMETER CHP1 – ISO 9060 FIRST CLASS
- ISO 9060:1990 Classification First Class
- Sensitivity: 7 … 14 µV/W/m²
- Spectral range (50% points): 200 … 4000 nm
- Maximum irradiance: 4000 W/m²
- Typical signal output for atmospheric applications:
0 … 15 mV - Non-linearity (0 … 1000 W/m²): < 0,2%
- Temperature dependence of sensitivity:
< 0,5% (-20 ... 50°C) - Operating temperature: -40 … 80°C
ROTATING SHADOWBAND IRRADIOMETER
- Uncertainty:
GHI in W/m²: <3,5% DNI in W/m²: <3,5% - Power consumption: <1W (average)
- Power supply: 12 VDC
- Temperature range: -30 … +65°C
SUN TRACKER STR 21G
- Accuracy: < 0,01°
- Angular resolution: 0,009°
- Maintenance-free driving technology HarmonicDrive®
- Torque: 12Nm
- Power requirements:
AC model: 100 … 240V AC, 50/60Hz, 13W
DC model: 18 … 30 V DC, 10W - Operating temperature: -40 … +50°C
SUN TRACKER STR 22G
- Accuracy: < 0,01°
- Angular resolution: 0,009°
- Maintenance-free driving technology HarmonicDrive®
- Torque: 24 (12+12) Nm
- Power requirements:
AC model: 100 … 240V AC, 50/60Hz, 13W
DC model: 18 … 30 V DC, 10W - Operating temperature: -40 … +50°C
SILICON IRRADIANCE SENSOR
- Accuracy at 25°: ± 1.5°C
- Temperatur compensation: compared to pyranometer within operating range
-20 … +70°C and vertical beam of irradiance ± 5% - Temperature range -20 … +70°C
- Current shunt (Si series):
0.1 Ohm (TC=20ppm/K) @ 1V + 20mA output
0.12 Ohm (TC=20ppm/K) @ 10V output - Non-linearity: ±0.5°
- Error: ±2.0°
- Solar cell: Monocrystalline silicon